Benötigen Sie weitere Informationen? Diese finden Sie in unseren zusätzlichen Ressourcen: Benutzerhandbuch | 280T – Spec Sheet | 280I – Spec Sheet | 280 – Spec Sheet | Kurzanleitung zum Laser-Vorhang | Messungen | Referenzkarte für RS-232-Befehlstabelle und Pinbelegung | Anschließen des MimioProjector an den Computer im Klassenzimmer: Anweisungen und Verbote | 280T – Hardware-Referenzkarte | 280I – Hardware-Referenzkarte | 280T – Anschlüsse Referenzkarte | 280I – Anschlüsse Referenzkarte | Anpassen der Referenzkarte für Ihren Laser-Vorhang | 280I – Montageanleitung für vertikale MimioProjector-Tische | 280T – Entfernungsrechner | 280I – Entfernungsrechner | USB-Verkabelungshandbuch für interaktive Geräte | Fehlerbehebung für Kabel
Foire aux questions
- I cannot bring up the calibration screen when using the MimioProjector™ device. Read More >>
If you open MimioStudio Notebook, does MimioProjector show up under Tools > Settings > Classroom Devices (on a PC) or Notebook > Preferences > Classroom Devices (on a Mac)? If not, there may be a connection issue. For your MimioProjector device to be interactive, you need to have an IR module installed. You also need to have the USB cable connected to the MimioProjector device from the computer, as well as either an HDMI or VGA cable. Make sure that you are using the standard USB cable that ships with your MimioProjector device. If a USB extender is required, we recommend using a USB 1.1 extender over a CAT5E or CAT 6 connection. We have tested this extension successfully up to 150 feet. Once the IR module is installed and the cables are connected, make sure that the module is turned on. To do so, press “Menu” on the MimioProjector remote and scroll down to “Interactive Settings.” It will say “IR Camera” if it is turned on, or “Off” if it is turned off. If you have the IR module turned on and both cables connected, but the MimioProjector device is still not interactive, contact customercare@boxlight.com for additional troubleshooting.
- I cannot turn on the IR module because it is greyed out in the MimioProjector menu. Read More >>
It is important to make sure that the IR module is inserted into the MimioProjector device correctly and that the pins are making a solid connection. If the IR module is installed correctly, make sure that both the USB cable and either an HDMI or VGA cable is connected to the MimioProjector device from the computer. Also make sure that you are using the standard USB cable that ships with your MimioProjector device. If a USB extender is required, we recommend using a USB 1.1 extender over a CAT5E or CAT 6 connection. We have tested this extension successfully up to 150 feet. Additionally, make sure that the 3D setting is off by going to Menu > 3D, using the MimioProjector remote. If this option is turned on, it disables the IR module. If none of the above steps resolves the issue, contact customercare@boxlight.com for additional troubleshooting.
- I can bring up the calibration screen when using the MimioProjector device, but it will not calibrate. Read More >>
This is most likely due to an issue with the stylus. First, try replacing the batteries in the MimioProjector stylus. If you still cannot calibrate after replacing the batteries, try using a known working stylus from another classroom. If using a known working stylus does not allow you to calibrate, there may be an issue with your IR module. Try replacing your IR module with a known working IR module from another classroom to see if this resolves the calibration issue. If none of the above steps resolves the issue, contact customercare@boxlight.com for additional troubleshooting.
- The MimioProjector device is connected, but there is no video displayed on the whiteboard. Read More >>
If you see the Mimio splash page when you power on the MimioProjector device, make sure that both an HDMI cable and a VGA cable are connected to the MimioProjector device from the computer and that you have the correct corresponding source selected on the MimioProjector remote. If the image is dark when you power on the MimioProjector device, there may be an issue with the bulb. If the bulb is completely burned out, you will see a red “Lamp” light on the MimioProjector device. If all of the cables are connected and you are still not displaying an image, or if it seems like the bulb is dimming or burned out, contact customercare@boxlight.com for additional troubleshooting.
- All of the LEDs on the MimioProjector device are illuminated and it will not power up. Read More >>
If all of the LEDs are illuminated, it means that the MimioProjector device is in firmware update mode, which is initiated by holding down the “Menu” button when powering on the MimioProjector device. Unplug all of the cables from the MimioProjector device, press the “Menu” button on the device a few times to make sure that it is not stuck in the down position, and then reconnect all of the cables. If all of the lights are still on when you power the MimioProjector device up, it means that it is still stuck in firmware update mode. Contact customercare@boxlight.com to request a replacement.
Hinweis: Für den interaktiven MimioProjector-Projektor ist MimioStudio-Software der Version 10 oder höher erforderlich, damit er ordnungsgemäß funktioniert.
Effectuez une recherche dans notre FAQ >>
Videos
Schauen Sie sich unsere Videos an, um das Produkt und die Einstellung besser zu verstehen.
Laser-Vorhang-Setup
Lösungen für häufige Interferenzprobleme
So machen Sie eine Tabellenoberfläche interaktiv
Schauen Sie sich unsere Videos an, um das Produkt und die Einrichtung besser zu verstehen. Wenn Sie zusätzliche informative Videos wünschen, besuchen Sie unseren YouTube-Kanal. >>
Software
Téléchargez les versions les plus récentes des logiciels et pilotes nécessaires au bon fonctionnement de votre produit.
Besoin de davantage d’assistance ?
Contactez notre service client >>